GYFXBY
GYFXBY
GYFXBY
GYFXBY

GYFXBY

All dielectric non-metallic flat self-supporting single tube optical cable
   Cable Cross-section

   Cable Specification

1. Introduction

Flat optical cable uses several fibers as optical communication medium. Widely used in Metro ODN network especially inside buildings which have multi-floors and room and two parallel fiber reinforced plastics (FRP) are its strength member. The cable is completed with a PE jacket.

2. Fiber color code

No.

1

2

3

4

5

6

Color

Blue

Orange

Green

Brown

Gray

White

No.

7

8

9

10

11

12

Color

Red

Black

Yellow

Violet

Pink

Aqua

3. Optical fiber type and properties

Item

Unit

Specification

G. 652D

Mode field diameter

1310nm

mm

9.2 ± 0.4

1550nm

mm

10.4 ± 0.5

Cladding diameter

mm

124.3~125.0

Cladding non-circularity

%

£1.0

Core concentricity error

mm

£0.5

Coating diameter

mm

245 ± 5

Coating/cladding concentricity error

mm

£10

Cable cut-off wavelength

nm

£ 1260

Attenuation Coefficient

1310nm

dB/km

£0.35

1550nm

dB/km

£0.21

Proof stress level

kpsi

100

Other parameters meet standard ITU-T G.652

Item

Unit

Specification

G. 657A1

Mode field diameter

1310nm

m

9.2 ± 0.4

1550nm

m

10.4 ± 0.5

Cladding diameter

m

124.3~125.0

Cladding non-circularity

%

1.0

Core concentricity error

m

0.5

Coating diameter

m

245 ± 5

Coating/cladding concentricity error

m

10

Cable cut-off wavelength

nm

1260

Attenuation Coefficient

1310nm

dB/km

0.35

1550nm

dB/km

0.21

Macro-bend loss (1 turn, 10mm radius)

1550nm

dB

0.75

1625nm

dB

1.5

Proof stress level

kpsi

100

Other parameters meet standard ITU-T G.657

4. Cable structure and parameter

Item

Contents

Unit

Value

Optical Fiber

/

/

4-12

Strength member

Material

/

FRP (*2)

Diameter

mm

1.6

 

 

Inner jacket

Diameter

mm

3.0±0.1

Material

/

PBT

Filler

/

Jelly

Color

/

Natural

 

Outer jacket

Diameter

mm

8.1(±0.4)×4.5±0.3)

Material

/

PE

Color

/

Black

Tensile performance

Short term

N

1350

Long term

N

400

Crush

Short term

N/100mm

2000

Long term

N/100mm

1000

Cable attenuation

dB/km

SM: 0.4 at 1310nm, 0.3 at 1550nm

Cable weight (Approx.)

kg/km

38

 

   Characteristics of Optical Cable

1. Min. bending radius

Static: 20 x Cable height
Dynamic: 40 x Cable height

2. Application temperature range

Operation: – 40℃ ~  +70℃
Installation: -30℃ ~ +70℃
Storage/transportation: – 40℃ ~ +70℃

3. Main mechanical & environmental performance test

Item

Test Method

Acceptance Condition

 

 

Tensile Strength IEC 60794-1-2-E1

– Load: Short term tension

– Length of cable:  50m

– Load time: 5min

– Fiber strain £ 0.6%

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

– Load: Long term tension

– Length of cable:  50m

– Load time: 5min

– Fiber strain £ 0.2%

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

 

Crush Test

IEC 60794-1-2-E3

– Load: Short term crush

– Load time: 1min

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

– Load: Long term crush

– Load time: 10min

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

Impact Test

IEC 60794-1-2-E4

– Points of impact: 3

– Times of per point: 1

– Impact energy: 1J

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

Repeated Bending IEC 60794-1-2-E6

– Bending radius: 20 x OD

– No. of cycle: 100

– Load: 20N

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

 

Torsion

IEC 60794-1-2-E7

– Length: 1m

– Twist angle: ±180°

– No. of cycle: 10

– Load: 20N

 

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

Kink

IEC 60794-1-2-E10

– Loop diameter:20 x OD

– No kink occurs.

Temperature Cycling IEC 60794-1-2-F1

– Temperature: -40~+70

– Time of each step: 8h

– Number of cycle: 2

– Loss change £ 0.5dB@1550nm.

– No fiber break and no sheath damage.

 

Water penetration

-Time:24h

-H:1m

-L:3m

 

-No water leakage

   Packing

Optional 2Km 3Km 4Km  5Km

La innovación impulsa el desarrollo, la calidad construye la marca

Desarrollamos, fabricamos y vendemos sistemas de acceso a comunicaciones ópticas y equipos terminales, y somos los primeros en lanzar una serie de productos únicos en el sector, que incluyen principalmente unidades de red óptica (ONU/ONT), terminales de línea óptica (OLT), pasarelas de voz (pasarelas VoIP) y otras series de productos de acceso, diseñados para satisfacer las necesidades de los operadores de telecomunicaciones y dedicados a proporcionar una experiencia de red de velocidad ultraalta a los usuarios de banda ancha de todo el mundo.

Ver todos los productos

Get In Touch With Our Experts

Tell us your business needs, and we will find the perfect solution.

Contáctenos